Sign In | Join Free | My ecer.co.uk |
|
Categories | Stationary Meter Test Bench |
---|---|
Brand Name: | GENY |
Model Number: | YC1893D |
Certification: | ISO, CE |
Place of Origin: | CHINA |
Payment Terms: | L/C,T/T,D/P |
Model NO.: | YC1893D |
Test voltage output(Phase-Neutral): | 3x(24V~288V)(or customized) |
Test current output: | 3x(1mA~100A) |
Frequency Range: | 45Hz~65Hz |
Voltage supply: | 3x220/380V±10%(or customized) |
Relative humidity: | 35%~85% |
Company Info. |
Guangzhou GENY Electric Co., Ltd |
Verified Supplier |
View Contact Details |
Product List |
>1. >Accuracy class : 0.05
>2. >Easy to calibrate closed I-P link meters with isolated current transformer(ICT)
Technical spec. | YC1893D-ICT-6 | YC1893D-ICT-12 | YC1893D-ICT-24 | YC1893D-ICT-48 |
Number of meter positions equipped ICT | 6 | 12 | 24 | 48 |
Accuracy class of ICT | 0.05 / 0.01 | |||
Accuracy | 0.05 | |||
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Standard Meter | SZ03A-K6 / SZ03A-K8 (customized) | |||
Scanning Head | YCG-S Series | |||
Voltage | ||||
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Current | ||||
Test current output | 3x(1mA~100A) | |||
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Phase angle | ||||
Range | 0~360⁰ | |||
Resolution | 0.01⁰ | |||
Setting accuracy | 0.1⁰ | |||
Frequency | ||||
Range | 45Hz~65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of error displays | 8 digitals | |||
Other | ||||
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
Ambient temperature | -10°C~+40°C | |||
Relative humidity | 35%~85% |
1. Installation of ICT in each meter position to test three-phase
meters with closed links between the current and voltage measuring
circuits (I-P links).
2. The meter test system can measure mechanical, electronic
mechanical and electronic meters by way of automatic,
semi-automatic or manual operation.
3.Meters under testing: 3P4W, 3P3W, 1P2W
4. Testing mode: active power, reactive power, and cross-connected
reactive power.
5. Simultaneously measure meters with the same specifications but
different meter constants.
6. Automatically position the rotor mark of the disc of the
mechanical meter, increasing efficiency.
7. Initiating the test and creep test.
8. Utilising the overload, short voltage circuit and open current
circuit protection functions.
9. The synchronised movement of the scanning heads streamlines the
control process.
10. The aluminium alloy is a lightweight yet durable and
corrosion-resistant material. The testing software, compatible with
Windows 2000, XP, 7, 8 and 10, includes a range of functional
modules for various modern energy meters. These modules facilitate
testing for real-time error, harmonic, demand and influence, among
others.
![]() |