Model Number: LD-200
Direction Detection: Supported
Auto Reset Time: 10 Minutes in Normal Mode
Certification: CE
Sensitivity Range: 0.015% to 0.8%
MOQ: 1
Delivery Time: 5 - 8 working days
Main Function: Vehicle Presence and Direction Detection
LD-200 Power Supply: 100-240VAC
Price: Negotiation
Detection Technology: Inductive Loop Vehicle Detection
Payment Terms: T/T,L/C,D/A,D/P,Western Union,Paypal,Alipay
Model: LD-200 / LD-202
Loop Inputs: CH1 Loop + CH2 Loop
Detection Channels: 2 Channels
LD-202 Power Supply: 12-24VAC/DC
Supply Ability: 1000 pieces per month
Product Type: Dual Channel Vehicle Loop Detector
Working Modes: 6 Selectable Modes
Brand Name: JUTAI
Independent Detection: CH1 and CH2 Independent Detection Supported
Packaging Details: Cartoon
Place of Origin: China
Sensitivity Levels: 8 Levels per Channel
Frequency Range: 20-100kHz
Frequency Levels: High / Medium-High / Medium-Low / Low
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

LD-200 Dual Channel Vehicle Loop Detector with Direction Detection for Parking Barrier Gate Access Control

LD-200 / LD-202 Dual Channel Vehicle Loop Detector

The JUTAI LD-200 / LD-202 is a dual-channel inductive vehicle loop detector designed for parking barrier gates, vehicle entrance and exit control, access control systems and traffic management applications.

Unlike a single-channel detector, the dual-channel design can connect two independent inductive loops, CH1 and CH2, allowing one detector to monitor two vehicle detection zones. The two-loop configuration also supports vehicle direction detection, making the detector particularly suitable for parking entrances, exits and bidirectional vehicle lanes.

The detector provides configurable presence and pulse relay outputs, eight sensitivity levels for each channel, four selectable operating frequency levels and six operating modes for different parking and traffic control requirements.


Key Features

Dual Channel Vehicle Detection

LD-200 / LD-202 supports two independent loop inputs:

  • CH1 Loop
  • CH2 Loop

Both channels can detect vehicles independently, allowing one detector to perform the functions normally requiring two separate single-channel detection circuits.

This makes it suitable for:

  • Parking entrance and exit lanes
  • Barrier gate control
  • Vehicle presence detection
  • Direction recognition
  • Traffic control
  • Vehicle passage logic

Vehicle Direction Detection

One of the key advantages of the dual-loop design is direction detection.

Two loops can be installed sequentially in the vehicle travel path.

For example:

CH1 → CH2

can be interpreted as one travel direction, while:

CH2 → CH1

can be interpreted as the opposite direction.

This allows the controller to distinguish vehicle entry and exit movements and generate the corresponding CH1 or CH2 relay output according to the selected operating mode.

The manual provides several direction-detection modes based on the sequence in which vehicles enter and leave CH1 and CH2.


Six Selectable Working Modes

The detector provides six operating modes for different control requirements.

Mode 1 — Direction Pulse Detection

Detects the sequence between CH1 and CH2 and produces a relay pulse after the vehicle leaves the corresponding loop.

Mode 2 — Direction Presence Detection

Uses the two-loop sequence to determine direction and generates a presence output according to the selected travel direction.

Mode 3 — Alternative Direction Presence Logic

Provides another dual-loop direction-control logic for applications requiring different vehicle entry and exit output timing.

Mode 4 — Independent Two-Channel Detection

CH1 and CH2 operate as separate vehicle presence detection channels.

This mode is useful when two independent loops need to be monitored without direction detection.

Mode 5 — Entry Pulse Detection

When a vehicle enters CH1 or CH2, the corresponding relay generates a pulse output.

Mode 6 — Exit Pulse Detection

The corresponding relay generates a pulse after the vehicle leaves CH1 or CH2.

This flexible mode structure allows the same detector to be used for both simple dual-loop detection and more advanced vehicle direction applications.


8-Level Independent Sensitivity Adjustment

Each channel provides 8 selectable sensitivity levels.

SensitivityLevel
Highest0.015%

0.02%

0.04%

0.08%

0.12%

0.2%

0.5%
Lowest0.8%

This allows the installer to adjust CH1 and CH2 according to:

  • Loop size
  • Vehicle type
  • Installation conditions
  • Required detection sensitivity

The manual also provides a special sensitivity increase function for applications such as trailers, where stable presence detection is important.


20–100kHz Adjustable Frequency

The operating frequency can be adjusted from approximately 20kHz to 100kHz using four selectable frequency levels:

  • High
  • Medium-High
  • Medium-Low
  • Low

Frequency adjustment is useful when multiple loops are installed close to each other because different frequency settings can help reduce interference between adjacent detection loops.


Automatic Reset and Permanent Presence

The detector supports two vehicle-presence behaviors.

Permanent Presence Mode

A detected vehicle can remain continuously present without automatic reset until the vehicle leaves the loop or the detector is manually reset.

Automatic Reset Mode

In Normal Mode, the detector automatically resets after approximately 10 minutes of continuous vehicle presence.

This can help recover from abnormal or unintended long-duration detection conditions.


Technical Specifications

ParameterSpecification
Product TypeDual Channel Vehicle Loop Detector
ModelLD-200 / LD-202
Detection Channels2
Loop InputsCH1 + CH2
LD-200 Power Supply100-240VAC
LD-202 Power Supply12-24VAC/DC
Sensitivity Levels8 Levels per Channel
Sensitivity Range0.015%-0.8%
Frequency Range20-100kHz
Frequency SettingsHigh / Medium-High / Medium-Low / Low
Working Modes6 Modes
Direction DetectionSupported
Independent CH1 / CH2 DetectionSupported
Presence DetectionSupported
Pulse OutputSupported
Automatic ResetSupported
Auto Reset TimeApprox. 10 Minutes
Permanent PresenceSupported
Trailer Sensitivity IncreaseSupported
CH1 OutputRelay COM / NO
CH2 OutputRelay COM / NO
Loop Fault IndicationLED Indication
ConfigurationDIP Switch
Main ApplicationParking / Barrier Gate / Vehicle Access / Traffic Control

Typical Applications

Parking Barrier Gates

Detects vehicles approaching, passing through or leaving a parking barrier gate and provides signals to the barrier controller.

Parking Entrance and Exit Direction Detection

Two loops installed sequentially can distinguish vehicle travel direction according to the CH1/CH2 detection sequence.

Two Independent Vehicle Detection Zones

When direction detection is not required, CH1 and CH2 can operate as two separate presence channels.

Vehicle Access Control

Can provide vehicle presence or pulse signals to compatible access-control and gate-control equipment.

Parking Counting and Traffic Logic

The CH1 → CH2 or CH2 → CH1 sequence can be used by the connected control system for vehicle flow and direction logic.


Loop Installation

The manual recommends configuring loop turns according to the total loop perimeter:

Loop PerimeterRecommended Turns
3–4m6 Turns
4–6m5 Turns
6–10m4 Turns
10–20m3 Turns
Above 20m2 Turns

For a typical dual-loop direction-detection installation, the manual illustrates CH1 and CH2 as two separate loops placed along the vehicle travel path, with approximately 1m spacing between the two detection loops.


Why Choose a Dual Channel Loop Detector?

Compared with a single-channel vehicle detector, the LD-200 / LD-202 provides several important advantages:

  • One detector supports two inductive loops
  • Supports vehicle direction detection
  • CH1 and CH2 can also work independently
  • 8 sensitivity levels for each channel
  • 6 configurable operating modes
  • Presence and pulse output options
  • 20–100kHz frequency adjustment
  • Automatic reset and permanent presence modes
  • Suitable for entrance and exit vehicle control

For parking system integrators, this makes the dual-channel detector particularly useful where two loops, vehicle direction recognition or more flexible barrier-control logic are required.

Loop Detector Connection Diagram
Indicators and Switches
  • Power LED (RED): Illuminates to indicate "Power ON"
  • CH1 Detection LED:
    • Steady On: Vehicle detection
    • Slow Blinking: Loop short circuit or insufficient twists
    • Fast Blinking: Loop open circuit or excessive twists
  • CH2 Detection LED:
    • Steady On: Vehicle detection
    • Slow Blinking: Loop short circuit or insufficient twists
    • Fast Blinking: Loop open circuit or excessive twists
Sensitivity Selection

Sensitivity and frequency adjustment is facilitated through 7-way and 10-way dip switch settings:

  • 8 different sensitivity settings available via dip switch configuration
  • Dip switches 6, 7, and 8 govern CH1 sensitivity (0.8 to 0.015)
  • Dip switches 3, 4, and 5 control CH2 sensitivity (0.8 to 0.015)
Sensitivity Selection Diagram
Switch Configuration

Switch 1 (S1) - Channel 1 Loop Function Selection:

  • DIP 1 & DIP 2: Special Sensitivity Increase For Both Trailer (Both Channels)
  • D3, D4, D5 and Switch 2 D1, D2: Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6 Normal mode)
  • D6 & D7 & D8 and Switch 2 D3 & D4 & D5: CH1 and CH2 Sensitivity Selection (Eight Levels)
  • D9 & D10 and Switch2 D6, D7: Frequency Selection (20 K to 100 KHz)
Switch Configuration Diagram 1 Switch Configuration Diagram 2 Switch Configuration Diagram 3 Switch Configuration Diagram 4
Reset Button Note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Guidelines
  • Coil cutting size should be rectangle: length 1.0 to 2.0 meters, width 0.8 to 1.2 meters
  • Avoid right angles at corners as much as possible
  • Use ferromagnetic wires for induction coil, total length up to 500 meters
  • Keep product plug and socket in vertical direction during installation
Coil Installation Overview Installation Orientation
System Integration

The JUTAI LD200/202 double-channel vehicle loop detector series, equipped with direction recognition function, is ideal for single-channel entry and exit scenarios when integrated with:

  • JUTAI One door controller (Model: AC-11)
  • JUTAI gate barrier (Model: BR-110)
  • JUTAI long-range RFID reader (Model: PUHF-9)
  • High-temperature resistance loop coils (Model: JTHT-11)
System Integration Diagram
Working Principle
Entry Process
  1. Car enters community/parking lot, pressing two loop coils simultaneously
  2. LD-200/202 triggers UHF reader at entrance
  3. UHF reader reads card ID and sends to controller via Wiegand output
  4. Controller verifies ID validity and outputs relay signal to open gate barrier
  5. Car enters, barrier arm lowers automatically
  6. LD-100/102 provides safety and anti-smashing functionality
Exit Process
  1. Car exits community/parking lot, passing inside UHF reader
  2. LD-200/LD-202 triggers UHF reader to read card and send ID to controller
  3. Controller verifies ID validity and outputs relay signal to open gate barrier
  4. Car exits, barrier arm lowers automatically
  5. LD-100/102 provides safety and anti-smashing functionality
Direction Recognition

The Direction Recognition Function ensures the double channels loop detector does not trigger the signal again when the car passes another UHF reader, recording only entry or exit records in the system.

Working Principle Diagram
Independent Operation Mode

The JUTAI LD-200/202 Double Channel Loop Detector can also function as two independent single-channel loop detectors, suitable for standard one-in and one-out parking lots.

This configuration provides cost-saving benefits by reducing hardware costs associated with using separate detectors for each function.

Independent Operation Diagram
Additional Application Diagram 2
Buy LD-200 Dual Channel Vehicle Loop Detector with Direction Detection for Parking Barrier Gate Access Control at wholesale prices
Send your message to this supplier
 
*From:
*To: Shenzhen Jutai Comm Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0