Sign In | Join Free | My ecer.co.uk |
|
Categories | Switch Life Tester |
---|---|
Brand Name: | Sinuo |
Model Number: | SN1113L |
Certification: | Calibration Certificate (Cost Additional) |
Place of Origin: | China |
MOQ: | 1 |
Price: | Negotiable |
Payment Terms: | L/C, T/T |
Supply Ability: | 20 Sets Per Month |
Delivery Time: | 30 Days |
Packaging Details: | Standard Exporting Plywood Case |
Standard: | IEC60884-1 Clause 23.2 |
Electric control method: | PLC+ touch screen |
Drive method: | Motor and electromagnet drive |
Tension application method: | Horizontal or vertical (optional) |
Test station: | Single station |
Tensile weight: | 30N, 40N, 60N, 80N, 100N, or 120N |
Company Info. |
Sinuo Testing Equipment Co. , Limited |
Verified Supplier |
View Contact Details |
Product List |
IEC60884-1 Clause 23.2 Cord Anchorage Force and Torque Test Equipment
Standard and Clause:
The Cord Anchorage Force and Torque Test Equipment is designed and manufactured according to the standard requirements of IEC60884-1 clause 23.2, IEC60745-1:2006, IEC60335-1 clause 25.15, IEC60598-1 clause 5.2.10.3, IEC60065 clause 16.5 and etc.
Prodcut Information:
The tester is used to conduct two tests of tension and torque at
the terminals of appliances (lamps) with power cords, appliances
intended to be permanently connected to fixed wiring with flexible
cords, and power cords such as household appliances, medical
equipment, etc.
The test method is to make a mark at the position of the wire
sample 20mm from the fixing device, gently apply the tension 25
times (or the number of times required by other standards) at a
rate of 1 time/second, and apply a torque near the exit of the
appliance for 1 minute. After the test, the displacement of the
marking position of the wire shall not exceed 2mm.
Technical Parameters:
Standard | IEC60884-1 Clause 23.2 |
voltage | 220V(AC)50Hz |
Electric control method | PLC+ touch screen |
Drive method | Motor and electromagnet drive |
Test station | Single station, vertical and horizontal cannot be tested at the same time |
Sample clamping method | Mechanical clamping, clamping point height can be adjustable |
Tensile weight | 10N: 1 PC, 20N: 3 PC, 30N: 2 PC (The tester can test the tensile weight of 30N, 40N, 60N, 80N, 100N, and 120N) |
Tension application method | Horizontal or vertical (optional) |
Torque weight | 4N, 5N, 7.5N, 12.5N, 17.5N, 21.25N (The tester can test the torque weight of 0.08N∙m, 0.1 N∙m, 0.15 N∙m, 0.25 N∙m, 0.35 N∙m, and 0.425 N∙m) |
Test times | 0~999999 times, can be preset |
Rally frequency | 1s/time, with tension sensing clip which can verify the tension retention time |
Torque time | 0-9999.9 seconds, can be preset |
Equipment size and weight | WDH=650×550×1200mm, approx. 110kg |
![]() |