Model NO.: YC1893R
Test voltage output (Phase-Neutral): 3× (24V - 500V) or customized
Power of the voltage output: 3×100VA
Test current output: 3× (1mA - 120A)
Power of the current output: 3×150VA
Frequency Range: 45Hz - 65Hz
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High-accuracy class of 0.01% energy meter test system for calibration of sub standard meter

High Accuracy 0.01% Three Phase Meter Test Bench for Prepayment Measurement

Product Description



YC1893R series is developed by our company with international advanced level of high-grade equipment. The overall accuracy levels up to 0.01 grades. It Is designed for institute of metrology, laboratory, EPRI and EEM equipment plants. It is mainly used to establish primary standards or the standards meter for the working standard .

This is a Stationary Three-phase Energy Meter Test System described here can simultaneously test 1…3, three-phase or single-phase electric energy meters, in which are 2-wire, 3-wire and 4-wire meters for active and reactive energy with accuracy of 0.1%, 0.2%, 0.5%, 1.0%, 2.0%.

The Meter Test System has following features and functions


  • Supporting parallel communication port to test smart meters through RS232 / Ethernet
  • Calibrating terminals on the rack for test bench verification
  • 1-phase energy meter for testing
  • 3-phase energy meter for testing
  • Accuracy Testing of reference standard meter
  • Pre-warming
  • Accuracy test as per IEC
  • Creeping test
  • Starting current test
  • Repeatability of error test
  • Dial test
  • Influence quantity test related to accuracy tests (Voltage, Frequency, reverse phase sequence, voltage unbalance)
  • Influence of harmonic component in voltage and current circuit as per IEC
  • Tamper and Fraud Monitoring
  • Sub Harmonics as per IEC standards (IEC 62052-11 / 62053-21/22/23)
  • Odd Harmonics as per IEC standards


Main Technical Data


  • Overall accuracy: 0.01%
  • Meter position: 1~3
  • Voltage output: 3x 480 VAC
  • Power voltage: 3x 70 VA or customized
  • Current output: 3x 1mA - 120A
  • Power current: 3x 300VA or customized
  • Stability: 30 ppm/h
  • Harmonic: 2nd - 41st

Product Parameters


Voltage240/415 V AC supply (+5% & -10%) or customized
Frequency50/60Hz ±2Hz
Power capacity> 3 × 6kVA
Ambient temperature-10°C … +40°C
Relative humidity35% … 95%
System GroundingNeutral solidly grounded
Surge protection level≥ 10 kV/120 Joules (10/1000µs)
Voltage
Test voltage output (Phase-Neutral)3× (24V - 500V) or customized
Power of the voltage output3×100VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.003%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd - 41st free programmable
Current
Test current output3× (1mA - 120A)
Power of the current output3×150VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.003%/h (integration time 150 s)
Load regulation from 0-max. load< 0.01%
Distortion factor< 0.3% for linear resistance load
Harmonics2nd - 41st free programmable
Phase angle
Range0 -- 360°
Resolution0.01°
Setting accuracy0.1°
Frequency
Range45Hz - 65Hz
Resolution0.01Hz


Our main products of electrical measuring equipment


  • Single/Three Phase Electric Energy Meter Test Bench
  • Single/Three Phase Portable Standard Meter
  • Single/Three Phase standard meter
  • Single/Three Phase Power Source
  • Single/Three Phase Portable Power Source etc.

Our Advantages


1.Pioneering Innovation:

Over 20 years of leadership in Electric Energy Meter measurement technology.

2.Expert R&D Team:

Committed to advancing Electric Energy Meter test instruments.

Catering to the diverse needs of a global clientele.

3.Professional Excellence:

Specialized training for all staff members.

Emphasis on high professional quality and skill.

4.ISO9001 Quality Management:

Adopted ISO9001 management practices.

Certified to ISO9001-2000 since 2002.

All staff trained in Total Quality Management (TQM).

5.Comprehensive Quality Control:

Full ISO9001 compliance across R&D, production, marketing, sales, and service.

Unwavering commitment to product quality.

6.Competitive Market Positioning:

A robust marketing network ensuring competitive pricing.

7.Unparalleled Customer Support:

A well-trained service team for prompt and effective support.

Offering maintenance, training, scheme design, and software updates.

8.Long-Term Customer Satisfaction:

Dedicated to providing sustainable and satisfactory customer experiences.

9.Partner with Excellence:

Join us for a partnership built on innovation, quality, and service.



*If you want to know more please check our official website:http://www.genymetertestequipment.com/

Buy High-accuracy class of 0.01% energy meter test  system for calibration of sub standard meter at wholesale prices
Send your message to this supplier
 
*From:
*To: Guangzhou GENY Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0