Sign In | Join Free | My ecer.co.uk
ecer.co.uk
Products
Search by Category
Home >

Digital Vital Signs Monitor Patient Care Monitor Hospital Patient Monitoring Equipment With 5 Para Patient Monitor

Categories Multi Parameter Patient Monitor
Brand Name: BIO
Model Number: PM-9000A+
Place of Origin: China
MOQ: 1 unit
Payment Terms: Credit card, Paypal, T/T
Delivery Time: 7 working - days since getting full payment
Packaging Details: Carton (38.5*34.5*30.5cm) 5kgs
Supply Ability: 1000 units / month
Screen: 12.1 Inch TFT True Color LCD Screen
Safty Standard: GB9706.1
ECG Waveform: Three-channel
Multi - Parameter: ECG, NIBP, SPO2, TEMP, RESP, Printer (Optional)
Applicant: Bedside Monitoring, ICU/CCU, Emergency Center, Family Monitoring, Etc.
Optional: Wall Bracket, Mobile Bracket, Backpack
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Digital Vital Signs Monitor Patient Care Monitor Hospital Patient Monitoring Equipment With 5 Para Patient Monitor

    Digital Vital Signs Monitor Patient Care Monitor Hospital Patient Monitoring Equipment With 5 Para Patient Monitor

    Standard Configuration

    1 PM-9000A+ multi-parameter monitor host 1 unit
    2 standard five-lead ECG lead connection cable 1 set
    3 standard adult blood pressure cuff 1 set
    4 adult blood oxygen probe 1 set
    5 temperature probe 1 set
    6 power plug cord 1 set
    7 ground wire 1 set
    8 User's manual 1 set

    Optional Configuration

    1 Built-in rechargeable lithium battery
    2 Dual-channel thermal printer
    3 Monitor cart/bracket/hanger
    4 Wrapped blood oxygen probe for children or newborns
    5 Blood pressure cuffs for children or newborns

    Specification

    1 ECG Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display
    Gain selection: ×1, ×2, ×0.25, ×0.5 four gears
    Frequency: 0.5Hz—100Hz
    Common mode signal rejection: greater than 70dB
    Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files
    Heart rate accuracy: ±5 beats/minute
    Calibration signal: 1mV (peak value, accuracy ±3%)
    ST segment detection: measuring range (-2.0mV---+2.0mV)
    Use standard: in line with ANSI/AMI EC13-2002 standard
    Response time: 1S
    Alarm mode: sound and light alarm
    Heart rate alarm preset range: (exceed the preset value alarm)
    The upper limit is adjustable between 1-255 times/minute
    The lower limit is adjustable between 0-254 times/minute
    2 NIBP
    Technology: Oscillographic Method
    Measurement method: reverse measurement data is more accurate
    Unit of measurement: mmHg/Kpa
    Overvoltage protection: double safety protection
    One measurement time: less than 45S
    Pressure range in cuff: 0-250mmHg
    Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value
    Initial inflation of cuff: 180mmHg (120mmHg for children)
    Cuff subsequent inflation: original systolic blood pressure + 30mmHg
    Blood pressure measurement range and error:
    Systolic blood pressure 60 mmHg~250 mmHg
    Average pressure 45 mmHg~235 mmHg
    Diastolic blood pressure 40 mmHg~220 mmHg
    Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater
    Response time: 1S
    Alarm mode: sound and light alarm
    Alarm prediction range and error: (Alarm when exceeding the preset value)
    Systolic blood pressure upper limit 1mmHg~255 mmHg
    ​Lower limit 0 mmHg ~255 mmHg
    Diastolic blood pressure upper limit 1mmHg~255 mmHg
    Lower limit 0 mmHg~254 mmHg
    Alarm error: ±1 mmHg
    Use standard: in line with ANSI/AAMI SP10-2002 standard
    3 SPO2 Range: 0-100%
    Accuracy: 1%
    Resolution: 1%
    Pulse frequency: 20-250 beats/min
    Response time: 1S
    Alarm mode: sound and light alarm
    Alarm range and error: (Alarm exceeding the preset value)
    Upper limit 1%~100%
    Lower limit 0%~99%
    4 TEMP Technology: Highly sensitive thermistor probe
    Body temperature measurement range: 20℃-- 45℃
    Resolution: 0.1%
    Body temperature accuracy: ±1℃
    Response time: 1S
    Alarm mode: sound and light alarm
    Alarm preset range and error: (Alarm when exceeding the preset value)
    The upper limit is adjustable between 20.1℃-- 45.5℃
    The lower limit is adjustable between 20℃ and 45.4℃
    Alarm error: ±1℃
    5 RESP Respiration rate range: 0-60 times/min
    Accuracy: ±1rpm
    Response time: 1S
    Gain options: ×1, ×2, ×4, ×0.5 four gears
    Alarm mode: sound and light alarm
    Alarm preset range and error: (Alarm when exceeding the preset value)
    The upper limit is adjustable between 10-100 times/minute
    The upper limit is adjustable between 0-99 times/minute
    Alarm error: ±1rpm
    6 Printer(Optonal) Specifications: Dual-channel thermal array recorder
    Printing method: real-time or event trigger recording waveform, text
    Resolution: Horizontal: 400dpi / Vertical: 800dpi
    Note: Date (year/month/day)/time (24 hours)
    Optional wall bracket, mobile bracket, backpack
    7 System

    Display: 12.1 inch TFT true color LCD display
    Safety standard: lec601-1 (International GB9706.1

    Features

    1 Brand-new high-precision module, with high measurement parameter accuracy, reliable quality and stable performance.
    2 Rotary shuttle operation mode, Chinese and English logo buttons, easy to learn and use, simple and intuitive operation.
    3 High-brightness and high-resolution 12.1-inch color TFT LCD display.
    4 Three-channel ECG waveform, seven-channel simultaneous display of ECG in all leads.
    5 Multiple display interfaces: single-lead, standard, large font, full-lead, and trend charts coexist.
    6 The new aluminum alloy internal structure design has good shock resistance and meets the use of mobile environments.
    7 The new digital blood oxygen technology is adopted to make the measurement of weak perfusion and finger shaking more accurate.
    8 ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis.
    9 The new fully-isolated floating design is resistant to defibrillation and high-frequency electrosurgical interference, and is suitable for use in harsh environments such as operating rooms and wards.
    10 NIBP dual overvoltage protection temperature drift control and other technologies ensure accurate measurement and protect patient safety.
    11 Powerful storage capacity, full parameter trend chart data throughout the whole process, ECG waveform storage and playback, and power-down save function.
    12 Automatic sound and light dual alarm, the upper and lower alarm limits can be set arbitrarily.
    13 Fanless design, dust-free, low power consumption, and improve the service life of the instrument.
    14 The body is light and firm, easy to carry, suitable for adults, children and newborns.
    15 Support wired and wireless networking functions, and support software online upgrades.
    16 Optional built-in removable rechargeable lithium battery, AC and DC dual purpose, light, energy saving and environmental protection.
    17 Optional built-in dual-channel thermal array recorder, real-time printing of waveforms and icons.
    18 It is widely used in bedside monitoring, ICU/CCU, emergency center, family monitoring, etc. in various departments of the hospital.
    19 Optional wall bracket, mobile bracket, and medical backpack.


    Buy Digital Vital Signs Monitor Patient Care Monitor Hospital Patient Monitoring Equipment With 5 Para Patient Monitor at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Wuxi Biomedical Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0