Sign In | Join Free | My ecer.co.uk
ecer.co.uk
Products
Search by Category
Home > Flow Sensors >

Insert doppler Ultrasonic Flow meter for volume flow measurement

Categories Ultrasonic Flow Meters
Brand Name: Purescience
Model Number: YE-TUF2000I
Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin: China
MOQ: 5 sets
Price: USD150-USD900
Supply Ability: 500 sets per month
Delivery Time: 3 weeks
Packaging Details: carton
Type: Insert
Name: Ultrasonic flow meter
display: LCD
Operation: Key boards
Output signal: 4-20 mA / OCT pulse / relay
Input: 3-way 4-20 mA (temperature, pressure and level)
Communication: RS485 / Modbus
Power supply: 8-36 VDC / 10-30 VAC
Pipe diameter: 15 mm - 6000mm
Pipe mount Material: weld steel, stainless steel, cast iron, copper / brass, cement pipe, aluminum
Accuracy: + / - 1%FS
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Insert doppler Ultrasonic Flow meter for volume flow measurement

    The doppler Ultrasonic Flow meter for volume flow measurement


    Function Description

    Our inserter type doppler ultrasonic flowmeter for liquids applications, including but not limited to the metering of cooling water and demineralised water, control of batching and blending operations, mass flow measurement, allocation

    measurement, district heating, irrigation, energy measurement, effluent, etc.

    • Independant of conductivity, viscosity, temperature, density and pressure
    • No moving or intruding parts, therefore no pressure loss or wear
    • Minimal operational and maintenance costs
    • Excellent long-term stability and reliability

    Data sheet

    Items

    Performance & Parameter

    Convertor

    Principle

    Transit-time ultrasonic flow meter

    Accuracy

    + 1%

    Operation

    4 keyboards operation

    Output signal

    1 channel 4-20mA, resistance 0-1K , accuracy 0.1%

    1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)

    1 channel relay output

    Input signal

    3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)

    Temperature transducer Pt100, heat / energy measurement

    Communication

    Galvanic isolation RS485, software upgrade by PC, MODBUS

    Signal cable

    Twisted-pair cable, 50m; RS485, transmission distance 1000m or above.

    Connect port

    Pipe material

    Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc

    Pipe Dia

    15 - 6000 mm

    Straight pipe

    Upstream: 10xDia, or downstream: 5xDia, and 30xDia from pump

    Metering

    Liquid type

    Single sonic wave transmittable liquid, such as municipal water, cooling

    water,

    seawater water, waste water, pure water, Sewage with particle content, such

    as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

    heating, ventilation ,air conditioner, power plants,


    Temperature

    -30-160℃


    Turbidity

    Up to 10000 ppm and less bubble


    Flow velocity

    0-7 m/s

    Work environment

    Temperature

    Convertor: -20-60 ℃, Transducer: -30-160℃

    Humidity

    Convertor: 85%RH, Transducer: submersible up to depth 2m

    Power supply

    DC8-36V or AC10-30V / 1.5W

    Dimension

    Convertor: 95*95*35mm


    Description:

    The pipe type inline ultrasonic flowmeter is a precision instrument designed for linear, bi/directional volumetric flow

    measurement of liquids. Flow measurement values can be output via the standard analog and-or pulse/frequency

    outputs. Through a user friendly operator interface (HMI) the unit can be set up for a wide range of applications.

    Next to actual volumetric flow measurement the unit can be configuredto perform flow totalization (plus, minus and

    sum). Also measurement and output of the liquid sonic velocity can be configured. Optionally the unit can be set to

    perform one of the following additional functions:

    • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
    • Batch function
    • Heat function, combining T1, T2 and volume

    Metering Diagram

    Flow measurement Heat measurement

    Reference chart

    Type

    Model

    Pipe dia (mm)

    Temperature

    Dimension (mm)

    Clamp on

    TS-2

    DN15-100

    -30-90℃

    45x25x32

    TM-1

    DN50-700

    -30-90℃

    64x39x44

    TL-1

    DN300-6000

    -30-90℃

    97x54x53

    Clamp on (high temperature)

    TS-2-HT

    DN15-100

    -30-90℃

    45x25x32

    TM-1-HT

    DN50-700

    -30-90℃

    64x39x44

    TL-1-HT

    DN300-6000

    -30-90℃

    97x54x53

    Insertion type

    TC-1

    DN80-6000

    -30-90℃

    190x80x55

    TC-2(lengthen)

    DN80-6000

    -30-90℃

    335x80x55

    Pipe type

    G3 (π type)

    DN15-25

    -30-160℃


    G2

    DN32/DN40

    -30-160℃


    G3

    DN50-6000

    -30-160℃



    Optional temperature transducer

    Specification

    Model

    Dia

    Temp.

    Water cut

    Accuracy

    Clamp-on temp. transducer Pt100

    CT-1

    >DN50

    -40-160℃

    No

    100+ 0.8℃

    Insertion temp. Transducer Pt100

    TCT-1

    Yes

    Insertion temp. Pt100 with pressure

    PCT-1

    No

    Insertion temp.Pt100 for small pipe D

    SCT-1

    <DN50

    Yes


    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Applications

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    I

    Model









    YF

    Electromagnetic flowmeter


    TF

    Turbine


    VF

    Votex


    LX

    Vane wheel


    T

    Ultrasonic



    E/F display mode

    E: compact/local display, F: remote display




    Pipe Dia

    Type (mm)




    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

    400, 500, 600, 800, 1000




    Code

    Accuracy




    1

    + 0.5% FS




    2

    + 1.0% FS




    3

    + 0.2% FS





    Code

    Type





    N

    Converter: 12 / 24 VDC, pulse output





    A

    Transmitter: 24VDC, 4-20mA outpt





    B

    Intelligent, Lion battery, no local display





    G

    Smart, local display, 4-20mA output





    C1

    Smart, local display, RS485





    C2

    Smart, local display, HART






    Code

    Type






    S

    Carbon steel housing






    L

    Stainless steel housing






    G

    High pressure housing






    HL

    316L electrode






    HTi

    Titanium electrode






    HTa

    Tantlum electrode






    HC

    Hastelloy-C electrode






    L1

    Liquid media






    L2

    Gas media






    P

    Pressure compensation






    T

    Temperature compensation






    PT

    Pressure&Temp. Compensation






    F

    PTFE liner






    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F,

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

    RS485, 316L electrode, liquid media meter, PTFE liner


    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Calibration

    Work shop

    Buy Insert doppler Ultrasonic Flow meter for volume flow measurement at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shanghai Xunhui Environment Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0